- Auto Lighting System[1]
- Circuit Breakers[10]
- Connectors[4]
- Other Connectors & Terminals[3]
- Terminal Blocks[6]
- Terminals[4]
- Contactors[5]
- Electrical Plugs & Sockets[4]
- Fuse Components[5]
- Fuses[6]
- Other Electrical Equipment[10]
- Power Accessories[10]
- Power Distribution Equipment[3]
- Voltage Regulators/Stabilizers[1]
- Relays[6]
- Other Switches[9]
- Rotary Switches[1]
- Transformers[4]
- Audio & Video Cables[1]
- Electrical Wires[1]
- Other Wires[2]
- Power Cables[10]
- Cable Sleeves[1]
- Other Wiring Accessories[2]
- Insulation Materials & Elements[10]
- Other Electronic Accessories[1]
- Other Electronic Components[1]
- Clamps[3]
- Starters[1]
- Multimeters[1]
- Pumps[1]
- Cast & Forged[1]
- Other Hand Tools[8]
- Hydraulic Tools[4]
- Other Power Tools[2]
- Contact Person : Ms. Wang Joan
- Company Name : Yueqing Laurence Imp. & Exp. Co., Ltd.
- Tel : 86-577-61780062
- Fax : 86-577-62762535
- Address : Zhejiang,Yueqing,#29, Huancheng East Road, Lushi, Yueqing City, Zhejiang Province, China
- Country/Region : China
- Zip : 325604
0.6/1 KV AI/XLPE/PE Power cable
0.6/1kV Al Conductor XLPE Insulated PE Sheathed Power Cable
Standard :
It is manufacture under GB/T12706-2002 standard(The same as IEC60502).
Application:
It is used to transmit and distribute power in power transmission and distribution system of 1kV. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Using features:
1. Rated voltage: Uo/U: 0.6/1kV
2. No. of core: Single-core, Two-core, Three-core, Four-core, Five-core,Three core and earth(Three primary conductor and one Neutral conductor), Three core and two((Three primary conductor and Two Neutral conductor), Four core and earth((Four primary conductor and One Neutral conductor).
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC.
4. D.C. resistance of the conductor complies with the stipulations of GB/T3956-1997.
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 2.5Uo+2kV/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.
(cable, power cable, power wire, electric cable, electrical cable, xlpe insulated cable, xlpe insulated power cable, pvc cable, pvc power cable, xlpe cable, xlpe power cable, pe sheathed cable, pe sheathed power cable, insulated cable)
0.6/1kV Al/XLPE/PE Power Cable(XLPE insulated cable,insulated power cable)
0.6/1 KV AI/XLPE/PE Power cable